Enferm. nefrol ; 21(3): 250-254, jul.-sept. 2018. tab
Artigo em Espanhol | IBECS | ID: ibc-174061

RESUMO

Objetivo: Determinar la utilidad de la ecografía-doppler vascular en la sala de hemodiálisis, en la identificación de pacientes portadores de catéter venoso tunelizado susceptibles de la construcción de una fístula arteriovenosa. Material y Método: Estudio descriptivo transversal en pacientes en hemodiálisis crónica portadores de un catéter venoso tunelizado. Se realizaron evaluaciones mediante ecografía portátil modo B, en 3 puntos diferentes de ambos brazos (proximal, medio y distal), y sobre 2 puntos de ambos antebrazos (proximal y distal), recogiéndose un promedio de las determinaciones realizadas. Se recogieron parámetros morfológicos cualitativos (presencia/ausencia de calcificación arterial) y cuantitativos (diámetro y profundidad) de la arteria radial, la humeral y la vena basílica de ambas extremidades superiores. Resultados: De las 63 personas en hemodiálisis, 9 eran portadores de un catéter tunelizado yugular (14,3%). Los valores medios de diámetro y profundidad (mm) fueron los siguientes: 4,7±3,0 y 9,2±2,7 (arteria humeral derecha), 4,8±0,6 y 10,5±3,3 (arteria humeral izquierda), 2,6±0,4 y 6,6±2,0 (arteria radial derecha), 2,7±0,7 y 6,0±1,6 (arteria radial izquierda), 4,3±0,6 y 10,1±2,1 (vena basílica derecha), 5,1±0,5 y 10,1±2,1 (vena basílica izquierda). En la mayoría de los casos (66,7%) se evidenció ausencia de calcificaciones, una placa aislada de calcificación en un caso (11,1%) y más de una en dos casos (22,2%). Conclusión: El ecógrafo portátil utilizado "in situ" en la sala de HD es una exploración útil para conseguir un cambio en el tipo de acceso vascular, es decir, para la conversión de un catéter venoso tunelizado en una fístula arteriovenosa en las personas en hemodiálisis crónica


Objective: To determine the utility of vascular ultrasound/Doppler in the hemodialysis unit about the identification of patients with tunneled venous catheter, who can be candidates for an arteriovenous fistula. Material and Method: Cross-sectional descriptive study in patients on chronic hemodialysis with tunneled venous catheters. Evaluations were carried out by B mode portable ultrasound, in 3 different points of both arms (proximal, middle and distal), and on 2 points of both forearms (proximal and distal), collecting an average in such determinations. Qualitative morphological parameters (presence/absence of arterial calcification) and quantitative parameters (diameter and depth) of the radial, humeral and basilic veins of both upper extremities were collected. Results: Of the 63 people on hemodialysis, 9 were carriers of a tunnelled jugular catheter (14.3%). The mean values of diameter and depth (mm) were the following: 4.7±3.0 and 9.2±2.7 (right humeral artery), 4.8±0.6 and 10.5±3.3 (left humeral artery), 2.6±0.4 and 6.6±2.0 (right radial artery), 2.7±0.7 and 6.0±1.6 (left radial artery), 4, 3±0.6 and 10.1±2.1 (right basilic vein), 5.1±0.5 and 10.1±2.1 (left basilic vein). In the majority of cases (66.7%), absence of calcifications was evidenced, an isolated plaque of calcification in one case (11.1%) and more than one in two cases (22.2%). Conclusion: The portable ultrasound system used "in situ" in the HD unit is a useful exploration to achieve a change in the type of vascular access, that is, for the conversion of a tunneled venous catheter to an arteriovenous fistula in people with chronic hemodialysis


Assuntos
Humanos , Cateterismo Venoso Central/enfermagem , Ultrassonografia Doppler em Cores/métodos , Derivação Arteriovenosa Cirúrgica/métodos , Insuficiência Renal Crônica/terapia , Diálise Renal/enfermagem , Cuidados de Enfermagem/métodos , Testes Imediatos , Unidades Hospitalares de Hemodiálise/estatística & dados numéricos
2.
Enferm. nefrol ; 19(4): 366-371, oct.-dic. 2016. tab
Artigo em Espanhol | IBECS | ID: ibc-159099

RESUMO

Introducción: La técnica de punción en área debe evitarse siendo la técnica escalonada de primera elección en la mayoría de los casos. Objetivo: Identificar a los pacientes portadores de una fístula arteriovenosa nativa que se puncionan mediante la técnica del área y que son susceptibles de cambiarla por la técnica escalonada a partir de los hallazgos obtenidos mediante la exploración mediante ecografía doppler. Pacientes y métodos: Los enfermos del estudio son enfermos tratados mediante hemodiálisis asistida (HD) tres veces por semana que cumplen los siguientes criterios de inclusión: Edad superior a 18 años, prevalentes en programa de HD crónica, con acceso vascular permanente tipo fístula arteriovenosa nativa humeral o radial y puncionado mediante la técnica del área. El método de exploración de la fístula arteriovenosa nativa fue la ecografía doppler portátil. Los parámetros ecográficos se determinaron por duplicado y fueron los siguientes: flujo sanguíneo de arteria nutricia (ml/min), diámetro y profundidad del segmento de vena arterializada que no se punciona (cm). Se diseñó un estudio transversal y observacional que se efectuó durante el mes de enero de 2016. Resultados: De un total de 63 pacientes prevalentes en HD crónica, se registraron: 24 fistulas arteriovenosas protésicas o catéteres y 39 fístula arteriovenosa nativa. De éstas, sólo 9 se puncionaban mediante la técnica de área (14,4%): 6 humerobasílicas y 3 humeroperforantes (edad media 73,0±13,3 años, 77,7% con alguna comorbilidad). Respecto al resultado de los parámetros ecográficos, se objetivó una media de 0.7± 0.3 cm de diámetro y 0.5± 0.3 cm de profundidad en el segmento de vena arterializada que no se punciona y el flujo medio de la arteria humeral fue de 1309,9± 966 ml/minuto. En la mayoría de los mismos fue posible utilizar directamente la técnica escalonada gracias a la ampliación de la zona puncionable de la vena arterializada utilizando la ecografía doppler. Y en dos enfermos, fue imprescindible la superficialización previa de la misma. Por tanto, todos los casos de técnica del área pueden ser potencialmente cambiados por la punción escalonada. Conclusión: 1) Se ha registrado una baja incidencia de utilización de la técnica de punción en área en nuestra Unidad de HD. 2) Según los resultados de nuestro estudio, es factible cambiar la técnica de punción en área por escalonada en todos los casos a partir de los parámetros morfológicos y funcionales obtenidos en la fístula arteriovenosa nativa. 3) La ecografía doppler portátil utilizada 'in situ' en la sala de HD es una herramienta valiosa que permite optimizar la técnica de punción de la fístula arteriovenosa nativa (AU)


Introduction: Most AVFs for hemodialysis (HD) should be punctured by the rope-ladder method. The area technique for AVF cannulation should be avoided whenever possible. On the other hand, cannulation guided by Doppler ultrasound (DU) can increase the success of difficult cannulation procedures. Objective: Identify the patients dialyzed through an AVF using the area technique for cannulation that are susceptible for changing to the rope-ladder technique based on the DU findings. Patients and methods: • During January-2016 we have performed a crosssectional observational study in the prevalent HD patients dialyzed through an AVF with two needles using the area technique for cannulation. • All patients were explorer by DU using GE Logic E(linear array 7.5 MHz) device. The following parameters were explored by DU: blood flow rate of the feeding artery (ml/min), diameter and depth of the arterialized vein segment that never was punctured (cm). All parameters by DU were measured in duplicated and the results were averaged. All determinations by DU were performed by the same explorer. Results: From 63 prevalent HD patients, 39 patients had AVF (61.9%) and, of them, only 9 patients (14.3%) were dialyzed through an AVF using the area technique for cannulation (mean age 73.0±13.3 years, 11.1% diabetic nephropathy, time on HD 53.6±26.9 months). All AVF were brachial artery-based AVF (6 brachiobasilic and 3 braquioperforating). The ultrasongraphic findings were the following: mean diameter 0.7± 0.3 cm, mean depth 0.5± 0.3 cm and mean flow 1309.9± 966 ml/min. Only two cases had the arterialized vein in more than 0.6 cm of depth and, therefore, they will need will perform a vein transposition procedure for apply the rope-ladder technique for cannulation. In the remaining cases (n=7), is possible to perform the rope-ladder technique immediately using DU by increasing the puncture zone extension in the arterialized vein. Conclusions: 1. It has been recorded a low incidence of area technique for AVF needling in our HD Unit. 2. It is feasible to change the needling AVF technique from area to rope-ladder technique in all cases by means of the morphological and functional parameters recorded in the AVF. 3. The portable DU used 'in situ' in the HD Unit is a valuable tool that allows to change the technique for AVF cannulation (AU)


Assuntos
Humanos , Masculino , Feminino , Fístula Arteriovenosa/enfermagem , Fístula Arteriovenosa , Ultrassonografia , Biópsia por Agulha/métodos , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/enfermagem
3.
Enferm. nefrol ; 18(3): 163-167, jul.-sept. 2015. ilus
Artigo em Espanhol | IBECS | ID: ibc-144425

RESUMO

Introducción: El uso de los nuevos diseños de agujas para la punción del acceso vascular puede mejorar la calidad de vida de los pacientes y los parámetros de eficacia hemodiálisis. Objetivos: Evaluar si hay diferencias en la intensidad del dolor percibido por los pacientes y la adecuación de hemodiálisis (índice Kt) después de la punción de la fístula arteriovenosa interna humeral a través de catéter-fístula o aguja estándar. Pacientes y métodos: Se realizó un estudio controlado, prospectivo, randomizado durante 4 meses (48 sesiones) para comparar la punción con catéter fistula (casos) versus a aguja estándard (controles) en pacientes en hemodiálisis prevalentes dializados por fístula arteriovenosa humeral. El mismo paciente era el caso y el control cuando se utilizó el catéter fístula (24 sesiones) y la aguja estandard de calibres equivalentes 15G (24 sesiones), respectivamente. El catéter fístula es una cánula de punción biocompatible compuesto por una aguja de metal interna destinado al pinchazo de la fístula humeral y un catéter de fluroplastico externa, de calibre15G, que permanece en el interior de la vena arterializada. El dolor relacionado, ya sea con punción o con la retirada de la aguja, se cuantificó mediante una escala validada visual analógica (EVA) y la escala McGill Pain Questionnaire Short Form (SF-MPQ). Resultados: Analizamos 14 pacientes prevalentes en hemodiálisis (edad media 68,4 ± 10,43 años; 71% hombres; 28,6% nefropatía diabética, tiempo medio en hemodiálisis 36,57 ± 18,28 meses) a través de fístula humerocefalica (50%), humerobasilica (21%) o humeroperforante (29%). Durante la punción y despunción de la fístula humeral, la EVA fue significativamente menor para el catéter fístula (2,07 ± 0,73 y 0,76 ± 0,39) en comparación con AS (2,88 ± 0,99 y 1,85 ± 0,95) (para ambas comparaciones, p <0,001). No se encontraron diferencias significativas en la escala SF-MPQ durante la sesión de hemodiálisis entre catéter fístula y aguja estandard (0,03 ± 0,07 frente a 0,11 ± 0,26, p = 0,13). La presión venosa (mmHg) registrada durante la primera y la última hora de la sesión de hemodiálisis fue significativa inferior para catéter fístula (171,2 ± 15,5 y 174,4 ± 16,7) en comparación con aguja estandard (194.9 ± 15.1 y 198.0 ± 20.1) (para ambas comparaciones, p <0,001). El índice Kt obtenido fue significativamente mayor para catéter fístula (51,1 ± 3,6 L) en comparación con aguja estandard (48,4 ± 3,1 L) (con p <0,001). No hubo episodios de extravasación con el catéter fístula y sólo uno con la aguja estandard (p = NS). Conclusiones: En relación con la aguja estandard, la utilización del catéter fístula disminuye el dolor percibido durante la punción o la retirada de la aguja (escala analógica visual), y la mejora la adecuación de la hemodiálisis (índice Kt) (AU)


Introduction: The use of new needle designs for VA puncture may improve the quality of life of patients (pts) and the parameters of HD efficacy. Objectives: To evaluate whether there are differences in the intensity of the pain perceived by the pts and HD adequacy (Kt Index) after brachial arteriovenous fistula (AVF) puncture through catheter-fistula (CF) or standard needling (SN). Patients and methods: We performed a prospective, controlled, nonrandomized study during 2 months (24 HD sessions) to compare needling by CF (cases) versus SN (controls) in prevalent HD pts dialyzed by brachial AVF. The same patient was the case and the control when the CF (12 sessions) and the conventional 15G needle (12 sessions) were used, respectively. The CF is a biocompatible puncture cannula composed by an internal metal needle intended to AVF puncture and an external fluroplastic catheter (15G) that remains inside the arterialized vein. The pain related either with needling or with needle withdrawal was quantified using a validated visual analogue scale (VAS) and the Short-Form McGill Pain Questionnaire (SF-MPQ). Results: We analyzed 14 prevalent HD pts (mean age 68.4 +/- 10.43 years; 71% male; 28.6 % diabetic nephropathy; mean time on HD 36.57 +/- 18.28 months) dialyzed by brachiocephalic (50%), brachiobasilic (21%) or brachioperforating (29%) fistula. During both needling and needle withdrawal, the VAS was significant lower for CF (2.07 +/- 0.73 and 0,76 +/- 0,39) compared to SN (2.88 +/- 0.99 and 1.85 +/- 0.95) (for both comparisons, p < 0,001). No significant difference was found when comparing the SF-MPQ score during HD session between CF and SN (0.03 +/- 0.07 versus 0.11 +/- 0.26, p = 0.13). The venous pressure (mmHg) recorded during the first and last hour of HD session was significant lower for CF (171.2 +/- 15.5 and 174.4 +/- 16.7) compared to SN (194.9 +/- 15.1 and 198.0 +/- 20.1) (for both comparisons, p < 0,001). The Kt index obtained was significantly higher for CF (51,1 +/- 3,6 L) compared to SN (48.4 +/- 3,1 L) (p < 0.001). No AVF leakage episodes were recorded with CF and only one by SN (p = NS). Conclusions: In relation to the standard needle, the use of fistula catheter decreases perceived pain in the puncture and removal of the needle (visual analog scale), and improving the adequacy of hemodialysis (Kt index) (AU)


Assuntos
Feminino , Humanos , Masculino , Diálise Renal/enfermagem , Catéteres/normas , Catéteres , Fístula/enfermagem , Medição da Dor/métodos , Medição da Dor/tendências , Estudos Prospectivos , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Biópsia por Agulha/enfermagem , Hemodinâmica/fisiologia , Equipamentos e Provisões/provisão & distribuição